CDSS Vendor #: 2000778CA BRN Provider #: 180955.0 from 330 Google reviews

RCFE Exiting Requirements: Doors, Hallways, and Exit Paths

| Posted in
Green emergency exit sign with a running figure and arrow, hanging in front of a red wall

Exiting is where fire clearance gets serious, because the whole point is getting people out of the building. Expect a minimum of two approved exits from the home, located remotely from each other. Exit doors serving residents are typically required to be at least 6 feet 8 inches tall with at least 32 inches of clear width when opened to 90 degrees. Sliding doors can often serve as exits when they provide that same 32 inch unobstructed opening. On double doors, the measurement is usually taken with only the normally active leaf open.

Hallways and exit paths

Hallways serving residents are generally required to be at least 36 inches wide, and exit paths inside and outside the home have to stay clear. No furniture, no equipment, no storage, nothing that would slow immediate use. This is the requirement most often violated after licensing rather than before, because a hallway that was clear at inspection slowly collects a wheelchair, a linen cart, and a folding table.

The route from common areas

From common areas serving residents, the route to an exterior door typically cannot pass through more than one intervening room, and it usually cannot route through storerooms, closets, garages, or similar spaces. It generally cannot pass through a kitchen when construction separates the kitchen from the adjoining rooms. Trace the route a resident would actually travel on the floor plan before you buy the house.

Door hardware

Hardware is its own category. Lockable doors and gates along the exit path have to open in the direction of travel without a key, tool, special knowledge, or special effort. Where the total occupant load, counting residents, staff, caretakers, and anyone else normally living or working there, is more than ten, operating the primary doorknob usually has to unlatch the dead bolt at the same time. Security chains are often allowed on exterior doors in homes with ten or fewer occupants if they need no key or tool, and manually operated flush or slide bolts are generally not permitted at any occupant load.

Escape and rescue openings

Emergency escape and rescue openings have to stay operable from inside without keys, tools, or special knowledge. Bars, grilles, screens, or covers are typically allowed only if they do not reduce the required clear opening, release from the inside without a key or tool or unusual force, and carry an approved exterior release for the fire department. Walk your home with a tape measure before your inspection and check every resident door, hallway, and window, and confirm the numbers with your local fire marshal, since some cities and counties enforce requirements beyond the state minimum. That one hour saves re-inspection fees and weeks of delay. NCPI walks owners through this ahead of the inspection and completes the entire facility application for $999, the most affordable in California, with 30 years of family experience. Call or text 619-322-9578 or email contact@ncpicare.com.